SSR125 Type Roots Blower for Fish Care

Method: Physical Treatment
Usage: Industrial, Agriculture
Roots Blower/Vacuum Pump: Roots Blower
Pump: Vacuum Pump
Lobe: Three
for: Fish Care
Customization:

Contact Supplier

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SSR125
Transport Package
Export Wooden Case
Specification
Roots Blower
Trademark
SSR
Origin
China
HS Code
8414599010
Production Capacity
10000 Units/Year

Product Description

SSR
Bore  50-200 
Suction-phase Air Volume(m3/min)  0.78-60
Discharge Pressure(kPa)  9.8-58.8


SSR-V
Bore  50-200
Suction-phase Air Volume(m3/min)  0.86-58.65
Discharge Pressure(kPa)  0-- -39.2

SSR-HB
Bore  50-250
Suction-phase Air Volume(m3/min)  1.24-90
Discharge Pressure(kPa)  9.8-78.4

SSR-VHB
Bore  50-250
Suction-phase Air Volume(m3/min)  0.86-87.3
Discharge Pressure(kPa)  0-- -44

Major Specifications of Type SSR-HB
Bore50 to 250A
Air Capacity 0.8-80m3/min
Pressure0.1-0.8kgf/cm2
Motor Power0.75-110kw

Standard Accessories
Common Base
V-belt Cover
Blower Pulley, Motor Pulley
V-belt
Suction Silencer(With Air Filter)
Safety Valve
Pressure Gauge
Lubricating Oil
Anchor Bolt
Type SSR-HB performance

The performance tables give the model number, bore, r. P. M., discharge pressure, air capacity and required power of the blower.

1 The air capacity in the tables is indicated in the standard suction state. The standard suction state herein mentioned is defined as the condition at 20oC temperature, 1.0332kgf/cm2 {101.3kPa} absolute pressure and 65% relative humidity.

2 The reference air capacity(0oC temperature and 1.0332kgf/cm2 {101.3kPa} absolute pressure is generally indicated in ) Nm3/min.
However, it may be converted into the standard air capacity by the following equation, if the suction pressure is equal,
QS=QN× 1.0732
Where QsStandard air capacity; And
QN: Reference air capacity;

3 The discharge air capacity can be converted into the standard air capacity by the following equation.
QsQd× [(1.0332+Pd)/1.0332]× (273+ts)/(273+td)
Where Qd: Discharge air capacity, inm3/min
Pddischarge pressure, inkgf/cm²
Ts: Suction temperature, inº C
Tddischarge temperature, inº C

4 According to the air capacity and discharge pressure as calculated abov e, the model number, bore, r. P. M. And required power can be found in the performance table.

5 The motor powers are indicated by color marking, and the motor powers to be used should be that indicated.

6 The choice is overlapped depending upon the type of blower, For reference, however, selection should be lower number blowers for the economy and higher number blowers for the sound level.

Send your message to this supplier

*From:
*To:
avatar Mr. Pengfei Li
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
1306
Year of Establishment
1991-05-24