Major Specifications of Type SSR-HB
Bore50 to 250A
Air Capacity 0.8-80m3/min
Pressure0.1-0.8kgf/cm2
Motor Power0.75-110kw
SSR
Bore |
50-200 |
Suction-phase Air Volume(m3/min) |
0.78-60 |
Diacharge Pressure(kPa) |
9.8--58.8 |
SSR-V
Bore |
50-200 |
Suction-phase Air Volume(m3/min) |
0.86--58.65 |
Diacharge Pressure(kPa) |
0-- -39.2 |
SSR-HB
Bore |
50-250 |
Suction-phase Air Volume(m3/min) |
1.24-90 |
Diacharge Pressure(kPa) |
9.8-78.4 |
SSR-VHB
Bore |
50-250 |
Suction-phase Air Volume(m3/min) |
0.86-87.3 |
Diacharge Pressure(kPa) |
0-- -44 |
Standard Accessories
Common Base
V-belt Cover
Blower Pulley, Motor Pulley
V-belt
Suction Silencer(With Air Filter)
Safety Valve
Pressure Gauge
Lubricating Oil
Anchor Bolt
Type SSR-HB performance
The performance tables give the model number, bore, r. P. M., discharge pressure, air capacity and required power of the blower.
1 The air capacity in the tables is indicated in the standard suction state. The standard suction state herein mentioned is defined as the condition at 20oC temperature, 1.0332kgf/cm2 {101.3kPa} absolute pressure and 65% relative humidity.
2 The reference air capacity(0oC temperature and 1.0332kgf/cm2 {101.3kPa} absolute pressure is generally indicated in ) Nm3/min.
However, it may be converted into the standard air capacity by the following equation, if the suction pressure is equal,
QS=QN× 1.0732
Where QsStandard air capacity; And
QN: Reference air capacity;
3 The discharge air capacity can be converted into the standard air capacity by the following equation.
QsQd× [(1.0332+Pd)/1.0332]× (273+ts)/(273+td)
Where Qd: Discharge air capacity, inm3/min
Pddischarge pressure, inkgf/cm²
Ts: Suction temperature, inº C
Tddischarge temperature, inº C
4 According to the air capacity and discharge pressure as calculated abov e, the model number, bore, r. P. M. And required power can be found in the performance table.
5 The motor powers are indicated by color marking, and the motor powers to be used should be that indicated.
6 The choice is overlapped depending upon the type of blower, For reference, however, selection should be lower number blowers for the economy and higher number blowers for the sound level.